OCK2

Fast response solution for microwave ovens

   Response is compared to other Shibaura flange type sensors


Sensing part: stainless steel   Wire: cross-linked PE, PVC, silicone rubber<br />Other options available
Sensing part: stainless steel   Wire: cross-linked PE, PVC, silicone rubber
Other options available

Features

Applications Microwave oven chambers (ambient)
Operating temperature -20 to +300℃ (from the tip of protection tube to the flange)
Thermal time constant τ ≒ 60 sec.
Dissipation constant δ ≒ 2mW/℃
Withstand voltage 1200VAC for 1 sec.
Consultation up to 2000VAC
Insulation resistance ≥100MΩ at 500VDC
Resistance R200 = 1kΩ Other options available
B constant B100/200 = 4537K Other options available

 Note 1) Values in the above table are for reference only.
 Note 2) Unless otherwise stated, the thermal time constant and the dissipation constant are measured in still air.